CGOLDENWALL Lab Centrifuge 6*20ml with Transparent Lid, 4000rpm Speed, 60min Timer, 1790xg RCF for Separation of Samples& Qualitative Analysis 5/7/10ml Vacutainer & 10/15ml Centrifuge Tubes Available

CGOLDENWALL Lab Centrifuge 6*20ml with Transparent Lid
  • STEPLESS SPEED REGULATION AND TIMING – You are able to set the time and speed according to your needs. Timing Range: 0-60 min, Maximum Speed: 4000 rpm.
  • INTERNAL ALUMINUM ALLOY ROTOR – With 6 holes, centrifugal capacity: 20ml * 6. Durable rotor ensures that the centrifuge tubes are not easily damaged. (NOTE: Considering the shipping damage, only plastic centrifuge tubes are included, the vacutainer tubes need to be prepared by yourselves.)
  • TRANSPARENT DUSTPROOF COVER – Test and centrifugation condition is observable through transparent lid. And the cover can better reduce the noise during operation.
  • SMALL SIZE AND STABLE OPERATION – Small size, easy to carry, stable operation, less vibration and wide applicability.
  • WIDE APPLICATION – It is suitable for the separation of plasma and serum, urea manufacturing, qualitative analysis in hospital laboratories and biochemical laboratories.
SKU: B08RJ8JFKV
Weight: 3.5 kg
Dimensions: 29.7 x 29.6 x 26.9 cm; 3.49 Kilograms
Part: YQ 98
Batteries Required: No
Batteries Included: No
Manufacture: CGOLDENWALL
Reference: YQ 98

Product Description

Lab centrifugeparameters base

Operating Steps

  • 1. Put the machine on a level and firm table, and keep the working room clean, dry and ventilated, the room temperature is 5-32℃.
  • 2. Clean the rotor and test tubes before operation.
  • 3. Put the test tubes (with the same weight) into the centrifuge hole.
  • 4. Put down the cover of the machine, adjust the timer as needed and turn on the power switch.
  • 5. Adjust the speed knob according to your requirements.
  • 6. After finishing the work, turn the speed knob to the lowest position and set the time to “0”, then cut off the power.
  • 7. Clean the container and rotor, then put down the cover.

Safety Attention

  • 1. Centrifuge tubes must be placed symmetrically.
  • 2. No-load operation without rotor is strictly prohibited.
  • 3. Check the rotor for corrosion damage before operation.
  • 4. Do not open the centrifuge cover when the rotor is running, and do not touch the running rotor.
  • 5. It is strictly forbidden to operate the rotor under unbalanced loading.

Centrifuge Maintenance

  • 1. Do not place any substance on the centrifuge cover. After each use, be sure to clean the inner cavity and rotor.
  • 2. If the centrifuge has not been used for a long time, the centrifuge cover should be opened for a period of time before use to dry the inner cavity.
  • 3. The carbon brushes of the motor should be replaced in time after 3000 hours of use to avoid wearing the commutator.

12345556
Voltage (V): 220 220 220 220 220 220
Maximum Speed (r/min): ≥3000rpm, ≤4000rpm±10% ≥3000rpm, ≤4000rpm±10% 4000rpm 4000rpm 4000rpm 6000rpm
Time Range (min): 0-120 0-120 0-60 0-999 0-30 5s-99min59s
Capacity: 20mlx12 20mlx12 20mlx6 10ml*6 15ml×8 8×2.0ml/1.5ml/0.5ml/0.2ml centrifuge tubes (with 0.5ml and 0.2ml centrifuge tubes),2x8x0.2ml PCR centrifuge tube
Maximum Relative Centrifugal Force: 2325(×g) 2325(×g) 1790(×g) 1920(×g) 2220 (×g) About 3000(×g)
Weight (kg): 8.3 8.3 4 4.7 12 1.5
Demension (mm): 350x330x400 350x330x400 280x280x290 260x280x210 330×300×280 175x156x125